
PLC / processor module
Bachmann MX220 processor module
Wind turbine controller CPU, repaired at component level and tested before return.
Vadodara lab
Component-level repair of PLCs, power supplies, HMIs, drives and I/O modules for plants in India and worldwide. Free diagnosis, a clear quote, and a 6-month warranty on every repair.
Or reach us directly:
Plants in these industries trust us with their critical electronics.






Type the model number from the label.
A few of the modules our engineers have brought back to life. Yours could be next.

PLC / processor module
Wind turbine controller CPU, repaired at component level and tested before return.

Control card / PCB
Industrial control card with failed components, traced and repaired without a schematic.

SMPS / power supply
24 V switch-mode power supply, rebuilt and tested at full rated load.

HMI / touch screen
Touch, display and boot faults fixed, with your project and settings kept.
If it is an electronic module from a plant, we can most likely fix it. These are the ten categories we see most often.
Siemens S7, Allen-Bradley ControlLogix, Mitsubishi, Bachmann. Memory, bus and power-rail faults.
Phoenix Contact Quint, Siemens SITOP, PULS, TDK-Lambda. Dead outputs, ripple, overheating.
Siemens Comfort, Schneider Magelis, Pro-face, Mitsubishi GOT. Touch, backlight and boot faults.
ABB, Danfoss, Yaskawa, Schneider Altivar, Fanuc. Gate-driver, IGBT and feedback faults.
ET 200, POINT I/O, Beckhoff, WAGO. Dead channels, drift and isolation failures.
Honeywell, Eurotherm, Omron, Yokogawa. Display, relay and sensor-input faults.
ABB, Areva MiCOM, Schneider. False tripping, dead displays, power-supply cards.
Profibus, Profinet and Ethernet cards, thyristor firing and drive control cards.
Gas detectors, lab pump controllers and analytical instrument boards.
No schematic? We trace the board, find the failed part and repair at component level.
Every unit follows the same six steps, and you can ask for a status update at any point.
We log the unit, serial number and your fault report, and photograph it on arrival.
Scope, thermal camera and component tests find the root cause. You get a quote.
Failed parts are replaced at component level. SMD and BGA rework where needed.
The unit runs under real load, not just power-on, before it can pass.
Final inspection, cleaning and coating, then the 6-month warranty is issued.
Packed in ESD-safe packaging and couriered back, or ready for collection.
Current, legacy and obsolete product lines. We are an independent repair company, not an authorised service centre.
We are not the manufacturer of these products. EESRS provides repair services only. Brand names and model numbers are shown to identify the units we repair.
Also: Phoenix Contact, Bosch Rexroth, Areva MiCOM, TDK-Lambda, Delem, Baumer, Branson, Agilent, Shimadzu, PerkinElmer, Waters, Julabo, Heidolph, Atlas Copco and more. Not listed? Send us a photo of the label.
Six promises behind every module we repair.
70+ industrial clients in 15+ industries send us their critical electronics.
On every repair: the parts we replace and our workmanship.
Most repairs in 3 to 4 working days, with priority for line-down breakdowns.
Engineers who repair at component level, not board swappers.
We find the fault and quote first. You pay only if you approve.
A clear quote before work starts, usually far below the cost of a new module.
Tell us the equipment, fault and turnaround you need. We diagnose it free and send you an exact quote before any work starts.
We find the fault first, then send you the exact price and turnaround. Nothing is repaired until you approve the quote.
When a line stops, a repaired module back in days costs far less than waiting weeks for a new one.
Packaging-line PLCs, autoclave and dryer controllers, HMIs.
Turbine controllers, pitch systems, inverter driver boards.
Burner management, gas detection, ESD and telemetry cards.
Servo drives, registration controllers, UV lamp ballasts.
Loom and jacquard controllers, autoconer drives, yarn sensors.
Robot controllers, spindle amplifiers, welding electronics.
Washdown HMIs, power supplies, pasteuriser controllers.
Server power supplies, precision AC controllers, transfer switches.
It covers the replaced components, our workmanship and the repaired fault. If the same fault returns under normal operating conditions within six months, we repair the unit again at no charge.
Yes. We inspect the unit, find the failed components and send you a quote. You pay only if you approve the repair. If you decide not to go ahead, there is no diagnosis fee.
Most repairs are completed in 3 to 4 working days. For a line-down breakdown, tell us when you send the unit and we will prioritise it.
Usually, yes. Because we work at component level, we can repair modules the manufacturer no longer supports. We source genuine obsolete parts or qualified equivalents.
Plants anywhere in India or abroad can courier their units to our Vadodara lab. Pack the unit in anti-static bags with padding, include a note with the fault, and WhatsApp us the courier details. We return it the same way once repaired.
No. EESRS is an independent repair company. We repair equipment from all of these manufacturers at component level, usually for much less than the cost of a replacement.
Annual repair contracts, bulk repairs or an unusual module: send us the details and our engineers will reply.
Email us the detailsWe are always looking for hardware engineers and SMD rework technicians who love fixing what others replace.
Send your CVTell us the make, model and fault. We reply with a diagnosis plan and a clear quote, and every repair carries a 6-month warranty.