Pharmaceutical
Batch, packaging and cleanroom equipment
Equipment reliability in pharma affects both output and compliance. We repair packaging-line PLCs, autoclave and freeze-dryer controllers, HMIs and inspection-camera electronics.
Case study
Problem: repeated communication drop-outs on a Siemens S7-1500 blister-packaging line.
Fix: degraded optocouplers on the backplane interface replaced and the board conformal coated.
Result: 40% less downtime on the line.